0x02 - Confirmed messages mode (LoRaWAN Confirmed messages on/off)0x03 - Full frequency range for ABP (requires device restart)Response: bb040400010001
bb - packet type0104 - device type0200 - Firmware version (v2.0)0301 - Board version (v3.1)Command to restart device.
Response: 2101f0ffa317
21 - packet type (0x21 - response)01 - port where request was madeF0 - commandffa3 - rssi (-92)17 - snr (2.3)Response: 2101bc000000dc
0x000000dc = 220 secResponse: 2101bd5fe3eac3
0x5fe3eac3 = 1608772291 (Thu, 24 Dec 2020 01:11:31 GMT)Response: 2101c00000000c00000019000000120000000400000000
0x0000000c - number of measurements performed0x00000019 - number of sent packets0x00000012 - number of received packets0x00000004 - number of device starts0x00000000 - number of packet retransmissionsResponse: 2101c10000000a00000001000000010000000000000000000000000000000000000000
Distribution by ranges (number of measurements):
0x0000000a – measurements <596 (3.18mA)0x00000001 – measurements <1096 (5.85mA)0x00000001 – measurements <1596 (8.51mA)0x00000000 – measurements <2096 (11.18mA)0x00000000 – measurements <2596 (13.85mA)0x00000000 – measurements <3096 (16.51mA)0x00000000 – measurements <3596 (19.18mA)0x00000000 – measurements <4096 (21.85mA)Response: 2101ca5fe4a1de
0x5fe4a1de = 1608819166 = Thu, 24 Dec 2020 14:12:46 GMTCommand: 0xCB 5FE4A0DC
0x5FE4A0DC = 1608818908 = Thu, 24 Dec 2020 14:08:28 GMTResponse: 2101cb00
0x00 - Success, otherwise - ErrorRequest, variant 1: 01003C
01 - Command003C - time in seconds (60 sec)Request, variant 2: 010000003C
01 - Command0000003C - time in seconds (60 sec)No response provided.
Request, variant 1: 02003C
02 - Command003C - time in seconds (60 sec)Request, variant 2: 020000003C
02 - Command0000003C - time in seconds (60 sec)No response provided.
Request, variant 1: 03003C
03 - Command003C - time in seconds (60 sec)Request, variant 2: 030000003C
03 - Command0000003C - time in seconds (60 sec)Response: 21030300
21 - packet type (0x21 - response)03 - Request port03 – Command00 - result (0 - success, 1 – error)Response: 21030400
21 - message code (0х21 - response)03 - request port04 - function code00 - warmup time value (0 - default value, 5 sec)Request: 050А
05 - function codeОА - sensor warmup time in seconds (0х0А - 10 sec)Response: 21030400
21 - message code (0x21 - response)03 - request port04 - function code00 - result (0 - success, 1 - error)Meter-switch is supplied with built-in firmware that ensures meter-switch operation with characteristics specified in this document.
Meter-switch configuration is performed using control commands sent to the meter-switch via wireless network.