Home → Knowledge Base → Battery Replacement
WARNING: Meter-switches are equipped with a non-rechargeable lithium-thionyl chloride (LiSOCl₂) battery ER34615M/T manufactured by Fanso. Attempting to recharge the battery may cause a fire!
The device transmits battery voltage data with every communication session. Monitoring is performed via:
If the meter-switch is found to be non-functional, first check the battery voltage in the monitoring system.
| Transmission Interval | 14 Ah Battery | 126 Ah Battery | 168 Ah Battery |
|---|---|---|---|
| 1 min | ~90 days | ~2 years | ~3 years |
| 2 min | ~180 days | ~4 years | ~6 years |
| 10 min | ~300 days | ~7 years | ~10 years* |
| 1 hour | ~3 years 150 days | ~10 years* | ~10 years* |
| 24 hours | ~10 years* | ~10 years* | ~10 years* |
* The maximum lifespan of lithium-thionyl chloride batteries is limited to 10 years due to natural self-discharge, regardless of capacity.
| Battery Capacity | Maximum Number of Packets |
|---|---|
| 14 Ah | 40,000 ± 10% |
| 126 Ah | 360,000 ± 10% |
| 168 Ah | 480,000 ± 10% |
IMPORTANT: Battery replacement must be performed by qualified personnel. Consumer repair and maintenance of the meter-switch is not permitted!
Opening the enclosure:
Disconnecting the old battery:
Installing the new battery:
Checking functionality:
Closing the enclosure:
For explosion-proof versions: Ensure the absence of an explosive atmosphere before opening the enclosure!
| Parameter | Value |
|---|---|
| Type | ER34615M/T |
| Manufacturer | Fanso |
| Voltage | 3.6 V |
| Capacity | 14,000 mAh (14 Ah) |
| Form Factor | D (34.2 mm × 61.5 mm) |
| Chemistry | LiSOCl₂ (lithium-thionyl chloride) |
| Temperature Range | -55°C to +85°C |
CRITICAL: Use only a non-rechargeable lithium-thionyl chloride battery cell ER34615M/T manufactured by FANSO. Using other batteries may result in malfunction, warranty void, or fire!
ENVIRONMENTAL: Lithium-thionyl chloride batteries are classified as hazardous waste. Do not dispose of them in household waste!
Disposal guidelines: